FAQ’s ❓

The desktop application has a password separate to that of your NVR or cloud account. When the programme starts, enter:

Username: admin
Password: 123456

 

 

System User Password
Cobra admin 00000
UNV admin 123456
Odyssey admin <blank>
Odyssey Turbo admin No default, set when first installed
XDH ADMIN 111111

The recommended format for a standard Ethernet patch lead is shown below. The official name for this standard is T-568B. The connector must be wired the same at both ends to make a ‘straight-through’ cable.

Any DVR
After backing up a file and the download has finished, you look in the folder where it should be and there is no file there. To fix this, close Internet Explorer, find its icon and right-click on it. Select ‘Run as Administrator’ and login to your DVR again. Now, the backup download will save correctly.

Cobra DVR (v15 firmware or higher)
If you find that the Backup button is grey and you can’t click it:

Go back to the landing page and select DVR Web Service



Then click ‘Login with administrator’

Make sure that the firmware on the DVR is as up to date as possible.

  1. Confirm that you cannot connect to [hostname].powerddns.com address from outside of the network (not on the local WIFI etc)
  2. Use command prompt on your PC to ping the PowerDDNS address. For example, type ping cctvdirect.powerddns.com and press enter. This will come back with an IP address.
  3. Ask the customer to use a tool such as YouGetSignal to find their external IP address.
  4. Compare the IP address from the command prompt with the one your customer gets from the website.
  5. If the IP address you get from the command prompt is different from the one the customer has, PowerDDNS has not updated. Ask the customer to reboot the DVR.
  6. If the IP address is the same there may be an issue with the port forwarding. Try and reboot the router as well as the DVR. If that don’t work use YouGetSignal to check ports are open.
  1. Connect the USB Drive to the USB port on the front of the DVR
  2. Press the menu button on DVR (Right click if using a mouse)
  3. Select Backup, then Backup from the drop down menu
  4. Input username and password
  5. Select Device: Device 1
  6. File format select AVI/RMS
  7. Select start and end date/time you require (Double click on time and date to amend)
  8. Select cameras you wish to back up from
  9. Press start for backup to start. Once complete, press OK.

To play back the recordings:

  • AVI format: double click the individual file to open in Media Player. If they do not play on your PC, we recommend https://mpc-hc.org/ as a better player.
  • RMS format: open BackupPlayer then press the Open Folder button to select the backup folder

The table below is intended as a general guide. Actual performance will depend on environmental conditions such as EM interference and quality of mains power supply.

CableAnalogueHD-SDIHD-TVIIP12v DC 1a
RG59 Shotgun200m20m200mNA70m
RG59 Pro Grade Shotgun250m80m300mNA70m
CAT5e300mNA200m100m70m
CAT6300mNA200m100m70m

Cobra (Old models)
If the end user has forgotten the password, or the user file has become corrupted and no one can login, follow this procedure.

On the front panel of the DVR, locate the Sequence/OK button in the middle of the 4 direction arrows. Press this 20 times in succession, then the ESC button. The screen will ask you confirm if you want to erase the setup file.

 

Cobra (New models)
Bring up the login window, then position the mouse pointer to the left of the OK button. Starting with the right mouse button, begin clicking right-left-right-left until a new menu appears. From here you can reset the system.

Cobra 960 & 960 Elite
Note that the Cobra960 only has the TB1 arrangement.

TB1
Pin no
Type

TB2
Pin no

Type
1POS +1SENSOR 5
2RS485 IN +2SENSOR 6
3RS485 IN –3SENSOR 7
4RS485 OUT +4SENSOR 8
5RS485 OUT –5GROUND
6GROUND6DO1 TTL
7RELAY 1 +7SENSOR 9
8RELAY COMMON8SENSOR 10
9SENSOR 19SENSOR 11
10SENSOR 210SENSOR 12
11SENSOR 311GROUND
12SENSOR 412DO2 TTL
  13SENSOR 13
  14SENSOR 14
  15SENSOR 15
  16SENSOR 16
  17GROUND
  18DO3 TTL

Cobra Elite D1

Pin noType
1RS485 +
2

RS485 –

3RELAY 1
4RELAY 1 COMMON
5

GROUND

6SENSOR 1
7SENSOR 2
8SENSOR 3

9

SENSOR 4

10

RELAY 2
11RELAY 2 COMMON
12GROUND
13SENSOR 5
14SENSOR 6
15SENSOR 7
16SENSOR 8
17RELAY 3
18RELAY 3 COMMON
19GROUND
20SENSOR 9
21SENSOR 10
22SENSOR 11
23SENSOR 12
24RELAY 4
25RELAY 4 COMMON
26GROUND
27SENSOR 13
28SENSOR 14
29SENSOR 15
30SENSOR 16

Your DVR may be set to output at Full HD (1080p) resolution, and the display you have plugged in does not support this. This is common on VGA monitors 19″ and below, and older ‘HD Ready’ televisions.

You should set the DVR to XGA or 1024×768 resolution, which is compatible with nearly all screens.

Cobra: Look for the two small switches next to the power connector. One will be pointing to ‘HD’, flip this down to ‘XGA’ and reboot the DVR.

Odyssey: HDMI/VGA resolution setting is available in the Display Output menu – if you have no other means of viewing the menu, you may have to attach a BNC monitor temporarily.